- Neon's Glow – The Blog of John DeArmond - https://www.johndearmond.com -

Using the Induction Heater – Plumbing

Every plumber and most anyone who has done much handyman work has run into that crufty old galvanized steel pipe that needs to be removed that just won’t come loose. The old pipe dope has set up hard as a rock and rust has made its contribution to the problem.

Traditionally, one would drag out the torch to heat the joint, perhaps starting a fire in the process :-). With induction heat, that isn’t necessary. Clean flameless heat “gits ‘er done” several times faster than a torch.

I asked a good friend of mine Bill Crow to come up with the cruftiest old piece of pipe he could find on his farm for me to do a demo with. Here’s what he found. Some inch and a half galvanized drain fittings.

Roy and his Enemy [1]

I decided to remove the side coupling, as it looked to be the toughest. Here’s the work coil set up and ready to heat. It is made from ordinary 4 gauge welding cable.

Pipe 02 [2]

Notice that the cable isn’t wrapped tightly nor particularly evenly. Neither are necessary. I picked the number of turns based on experience.

Pipe 03 [3]

An approximately 2.5 minute shot of juice produced the temperature that you see here. At that temperature the coupling has expanded and the pipe dope has become plastic again. Note that in this demo I’m using Roy 1.0.  He generates only about half the power of Roy 2.2 and the upcoming 3.0.

Pipe 04 [4]

Here I’m unscrewing the coupling. Notice that I’m choked up on the pipe wrench handle. Very little force was needed to break loose the fitting and unscrew it.

Pipe 05 [5]

The finished fitting. Notice how the old pipe dope has smeared. It was soft and plastic at almost 450 degrees! Notice too that there are no stain nor burn marks on the pipe nor the bench seat below the fitting. That could just as well been wood. Completely safe from fire.

An obvious question is, “What if the pipe is full of water?” Well, the same situation exists as with a torch. If the pipe is really full of water, especially under any kind of pressure then the heater isn’t going to do much. It will heat the fitting and the water to the boiling point and that might be enough. If there is just a little water then the heat will boil it away. Just takes a little longer.

Another question that comes up all the time is “Can I do copper?” The answer right now is unfortunately no. Copper is so electrically and thermally conductive that it is very difficult to pump enough power into a copper fitting to reach sweating temperature. We’re working on the problem but it may be that there isn’t enough power available from a 120 volt outlet to do the job, at least not on 1/2″ and above fittings. Stay tuned for future developments.